產(chǎn)品詳情
Detailed inbation for: XT2N 160 TMG 160-480 3p F F
This page contains technical data sheet, documents library and bs to offering related to this product. If you require any other inbation, please contact us using b located at the bottom of the page.
XT2N 160 TMG 160-480 3p F F
General Inbation
-
Extended Product Type:XT2N 160 TMG 160-480 3p F F
-
Product ID:1SDA067726R1
-
EAN:8015644016227
-
Catalog Debion:XT2N 160 TMG 160-480 3p F F
-
Long Debion:C.BREAKER TMGX XT2N 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMG R 160-480 A
Categories
- Products ? Low Voltage Products and Systems ? Circuit Breakers ? Moulded Case Circuit Breakers ? Tmax XT
Ordering
-
EAN:8015644016227
-
Minimum Order Quantity:1 piece
-
Customs Tariff Number:85362090
Dimensions
-
Product Net Width:90 mm
-
Product Net Height:130 mm
-
Product Net Depth / Length:82.5 mm
-
Product Net Weight:1.571 kg
Container Inbation
-
Package Level 1 Units:1 piece
-
Package Level 1 Width:130 mm
-
Package Level 1 Height:208 mm
-
Package Level 1 Depth / Length:145 mm
-
Package Level 1 Gross Weight:1.65 kg
-
Package Level 1 EAN:8015644016227
Additional Inbation
-
Circuit Breaker Type to be Associated:Generator Protection
-
Current Type:AC/DC
-
Electrical Durability:120 cycles per hour
8000 cycle
-
Mechanical Durability:Nr. Operations 240 cycles per hour
Nr. Operations 25000 cycle
-
Number of Poles:3
-
Opening Time:CB with SOR 15 ms
CB with UVR 15 ms
-
Order Multiple:1 piece
-
Power Loss:at Rated Operating Conditions per Pole 16.15 W
-
Product Main Type:SACE Tmax XT
-
Product Name:Moulded Case Circuit Breaker
-
Product Type:CB
-
Rated Current (In):160 A
-
Rated Frequency (f):50 / 60 Hz
-
Rated Voltage (Ur):690 V
-
Rated Impulse Withstand Voltage (Uimp):8 kV
-
Rated Instantaneous Short-Circuit Current Setting (Ii):480 A
-
Rated Insulation Voltage (Ui):1000 V
-
Rated Operational Voltage:690 V AC
500 V DC
-
Rated Service Short-Circuit Breaking Capacity (Ics):(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
-
Rated Ultimate Short-Circuit Breaking Capacity (Icu):(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
-
Rated Uninterrupted Current (Iu):160 A
-
Release Type:TM
-
Setting Range:112...160 A
-
Standards:IEC
-
Sub-type:XT2
-
Terminal Connection Type:Fixed Circuit-Breakers
-
Version:F
Certificates and Declarations (Document Number)
-
Data Sheet, Technical Inbation:1SDC210100D0204
1SDC210099D0204
-
Declaration of Conbity - CE:9AKK106713A5901
-
Environmental Inbation:1SDL000190R0001
-
GL Certificate:1SDL000163R0093
-
Instructions and Manuals:1SDH000721R0001
-
LR Certificate:1SDL000163R0100
Classifications
-
ETIM 4:EC000228 - Power circuit-breaker for trafo/generator/installation prot.
-
ETIM 5:EC000228 - Power circuit-breaker for trafo/generator/installation prot.
-
ETIM 6:EC000228 - Power circuit-breaker for trafo/generator/installation prot.
-
ETIM 7:EC000228 - Power circuit-breaker for trafo/generator/installation protection
-
Object Classification Code:Q
-
UNSPSC:39120000
- WEEE Category:5. Small Equipment (No External Dimension More Than 50 cm)